Estimation of Fat in Milk Samples
Introduction
Milk fat measurement is a common task in the dairy industry, because milk fat content is one factor that determines milk price and is necessary to know for casein/fat ratio normalization. It is also important for the dairyman to know milk fat content exactly: discrepancies in the results of milk fat tests (usually performed in the dairy industrial plant) have economic relevance. In addition, a low milk fat content could indicate the existence of animal health deficiencies.
Principle
The fat can be separated from fat-containing milk/milk powder through the addition of sulphuric acid. The separation is made by using amyl alcohol and centrifugation. The fat content is read directly on a special calibrated butyrometer after centrifugation.
Apparatus
Good quality balance Special butyrometer Caoutchouc stoppers Pipettes - 1 and 10 ml Centrifuge, - 1200 rpm, equipped with heating element
Reagents
90% Sulphuric acid 100% Amylalcohol
Procedure
Mix the milk sample (temperature about 20°C) thoroughly, taking care to minimize incorporation of air. Allow the sample to stand for a few minutes to discharge any air bubbles. Mix gently again before pipetting. Pipette sequentially into the butyrometer: 10 ml of 90% sulphuric acid. 10.75 ml milk (must not be mixed with the acid). Note: Pipette the required volume of milk into the butyrometer. Care must be taken to avoid charring of the milk, by ensuring that the milk flows gently down the inside of the butyrometer. It then rests on top of the acid. 1 ml amyl alcohol some drops of distilled water Clean the neck of the butyrometer with a tissue or dry cloth. Close butyrometer with caoutchouc stopper and shak until the milk was dissolved. The butyrometer was turned upside-down 5 or more times. Spin in the Gerber centrifuge for 15 minutes. The fat column was adjusted by using the stopper, so that it will be in the graduated part of the butyrometer. The fat percentage was read directly. Note: Measurements should be carried out in duplicate.
Hazards
Sulphuric acid is toxic, highly corrosive and will cause severe burning if it comes in contact with the skin or eyes. When mixing the butyrometer contents, considerable heat is generated.
If the stopper is slightly loose, leakage may occur during mixing, centrifuging or holding in the water bath.
Precautions
Wear protective eye goggles Avoid all spillage and dropping of sulphuric acid from acid dispensers. When mixing, hold the butyrometer stopper firmly to ensure that it cannot slip. Use a cloth or glove to protect the hands when mixing. Do not point the butyrometer at anyone when mixing.
Authors* * Sanjeev Sharma1, BR Yadav1, Aarti Bhardwaj2, Shalini Jain3 and Hariom Yadav3 1Livestock Genome Analysis Lab, 3Animal Biochemistry Division, National Dairy Research Institute, Karnal- 132001, India 2Meerut Institute of Engeenering and Technology, Meerut, U.P., India
- 上一篇
Direct Intrathecal Drug Delivery in Mice for Detecting In Vivo Effects of cGMP on Pain Processing
Intrathecal delivery of drugs is an important method in pain...
- 下一篇
Detection of Transcriptional Activators, Co-activators, and Chromatin Remodeling by Chromatin Immuno
Investigation of DNA–protein interactions is a key approach ...