Login
欢迎浏览恩派尔生物资料网
我要投稿 请登录 免费注册 安全退出

您现在的位置是: 首页 > 实验方法 > DNA实验

DNA实验

Removal of 32P-ATP from Oligonucleoi

2024-10-09 DNA实验 加入收藏
1. Prepare Whatman DE-52 according to manufacturers specifications. Equilibrate

1. Prepare Whatman DE-52 according to manufacturers specifications. Equilibrate at store with 0.02% Sodium azide.

2. Plug a 1 mL (blue) pipet tip with Siliconized glass wool. Add 500 ml of 50:50 DE-52 slurry. Pack into a 250 mL column by gently forcing the fluid through with a P-1000 pipetter.

3. Rinse column twice with 1 mL TE, forcing through with a P-1000.

4. Add 200 ml TE to Kinased Oligo. Apply the solution to the column and gently force though with the P-1000.

5. Elute nucleotides by washing 4 times with 1 mL 0.2 M NaCL in TE. Monitor counts removed. Most residual ATP should be removed after the first 2 rinses.

6. Elute the labeled oligonucleotide with 500 ml 1 M NaCl in TE. Repeat 3 times, collecting each rinse separately. The first rinse should contain most of the oligonucleotide.

7. Up to 10% of the counts may remain on the column.


文章底部广告位

文章评论